Type A RCDs

Conforms to BS7288:2016 BS1363-2, and meets latest IET Wiring Regulations

Continues to protect with Lost Neutral /pulsating DC earth fault

Designed, Tested and Certified in the UK

High EMC Immunity dramatically reduces nuisance tripping

The Timeguard RCD11WPVN Valiance+ is a single-gang, passive RCD-protected fused connection unit, designed to prevent electric shock and fire hazards. Compliant with BS7288:2016, it features 30mA RCD protection, fast tripping response, and a latching mechanism to restore power after a mains failure—ideal for freezers and essential electrical appliances.

£19.45 + VAT

(incl. VAT £23.34)

Category: Supplier: Timeguard

Description

RCD Protected Passive Single Gang Fused Connection Unit

Reliable RCD Protection for Safer Electrical Installations

Timeguard RCD11WPVN Valiance+

The Timeguard RCD11WPVN Valiance+ is a passive RCD-protected single-gang fused connection unit, designed to enhance electrical safety by protecting against electric shock and fire risks. Featuring advanced RCD technology, it meets the latest BS7288:2016 standard, ensuring improved immunity to interference from mobile phones and electronic devices—minimising nuisance tripping.

This fused connection unit is ideal for both residential and commercial applications, including appliances that require uninterrupted power after a mains failure, such as freezers and security systems.

Key Features

  • Enhanced Electrical Safety – Provides 30mA RCD protection, reducing the risk of electric shocks and fire hazards.
  • Passive (Latching) RCD – Automatically restores power after a mains failure, making it perfect for critical appliances.
  • Quick Reaction Time – Trips in less than 40 milliseconds at 150mA residual current for rapid fault detection.
  • Compact & Versatile Design – Fits standard BS4662 recessed or BS5733 surface mount boxes with a minimum 25mm depth.
  • Durable & Compliant – Fully compliant with BS7288:2016, ensuring high performance and reliability.

Why Choose This Product?

The Timeguard RCD11WPVN is designed for easy installation and long-term reliability. Its passive RCD function ensures that power remains on after a supply interruption, preventing disruption to essential appliances. Additionally, its robust design and high-quality components make it suitable for homes, offices, and commercial installations.

Why Buy From Electrical4Less?

At Electrical4Less, we provide:

  • Competitive prices on all Timeguard products
  • Fast UK delivery for quick project completion
  • Expert customer support to assist with your purchase
  • Genuine products with full manufacturer warranties

Downloads

View Product Data Sheet Instruction Manual

Additional information

Brand

Timeguard

Cut off time for Dispatch Delivery: Mon-Thu 3 PM *
Cut off time for Saturday Delivery: Friday 3 PM *
All orders placed on Sat/Sun will be dispatched on Monday.
© 2025 Electrical 4 Less
Electrical 4 Less

    Electrical 4 Less
    whatsup-logo
    Next Day Delivery
    Cut-Off Time and Order Information
    To ensure your order qualifies for next day delivery, please place your order by 3:00 PM. This is subject to all items being available on the shelf at the time of your order. For orders where the total value exceeds £150 + VAT (double our standard carriage-paid order value of £75 + VAT), we are happy to split the delivery into two shipments if some items are needed urgently and others are not immediately available. If you have any questions or need further assistance, feel free to reach out to us via WhatsApp for live support. We're here to help!
    Delivery Policy
    Free Next-Day Delivery Over £75 + VAT:
    Orders above £75 + VAT qualify for free next-day delivery via DPD for in-stock items. While we strive for timely dispatch, we recommend placing orders early to avoid potential delays. Once dispatched, unexpected issues may arise despite the courier’s efforts.

    Orders Below £150 + VAT:
    To keep costs manageable, we dispatch your order once all items are ready, including products with longer lead times.

    Need items faster? You can pay for an additional delivery service to receive in-stock items sooner. Simply email us with your order details, and we’ll send you a payment link for the extra delivery cost.

    Orders Above £150 + VAT:
    For larger orders, we can split delivery at no extra cost. In-stock items will be sent immediately, with the remaining items dispatched once available.
    Dispatch Times
    Items with Lead Times (e.g., 1–3 Working Days):
    This means we need to source the product from our supplier before sending it to you. The estimated dispatch time is displayed on each product page.

    Out of Stock at Supplier:
    If an item is unavailable at the supplier, we will contact you promptly. You’ll have the option to choose an alternative product or request a full refund.